HighFinesse-Ångstrom Wavelength meters

Current Sources

Precision Current Sources

Noise Spectrum
Current- and Voltage-Characteristics

The use of current sources in precision-application re-quires high accuracy, stability and low-noise currents. Current sources by HighFinesse were designed to meet these requirements.

The diagram shows the FFT-spectrum of the BCS 3/15 current source between 0 and 2500 Hz. The spectrum shows a noise level below -108 dB VRMS . Each device is tested carefully before delivery, so the witching time and noise characteristics are included in the manual.

The measurement was taken at 3A and an ohmic load of 1 Ohm.
Trigger: AC line; Average: 128; Voltage noise < 4 µVRMS

For further information about our current sources please download the
» Current source broschure 2011 [pdf-Version, 234 kB] or » contact us