HighFinesse
Products HighFinesse distributors worldwide Our services   Contact to HighFinesse
Wavelength meters Current sources Laser systems  
Ångstrom

Home

Products

Wavelength meters
HDSA
LSA
WS5
WS6
WS7
WSU
Options

Current sources
Power classes
Response time
Noise Spectrum

Laser Drivers

Ti:Sa Laser

InGaAs Camera

Distributors

Service

Contact


HighFinesse-Ångstrom Wavelength meters

Laser Spectrum Analyser - LSA

Absolute accuracy: 6000 MHz, resulution: 1000 MHz

 Sensitivity: 5 nJ @ 633 nm
 Low stage spectral resolution: (λ/ΔλFWHM): 500
 High stage spectral resolution (λ/ΔλFWHM): 20000 (SM fiber),
    10000 (50µm fiber)
 max. spectral range: 3 THz
 linewidth accuracy : 10%
    min. linewidth Δλ/λ= 2*10-5 (e.g. 10pm @ 633nm)
    max. linewidth: 1.5 THz
 Built-in light source for autocalibration

  NEW: Mid-IR Laser Spectrum Analyser: LSA IR-III
Click here for more information!

The Laser Spectrum Analyser is designed to analyse the multi-line or broadband spectrum of light sources like cw and pulsed lasers, gas discharge lamps, super luminescence diodes, semiconductor laser diodes and LEDs.

Technical Data  LSA
Measurement range [nm]   Standard

UV

IR
350-1120

248-1100

800-1750
yes

yes

yes
Absolute accuracy(4)  

192-370 nm [pm](1)

370-1100 nm [MHz]

1100-2250 nm [MHz]
6

6000

12000
Quick coupling accuracy (with MM fiber) 12000
Wavelength deviation sensivity  

248-370 nm [pm]

370-1100 nm [MHz]

800-1750 nm [MHz]
5

3000

5000
Spectral resolution  

Standard, UV

IR
20000(SM),10000(MM)

4000(SM),2000(MM)
Linewidth High stage(2)  

Accuracy

Min. linewidth [MHz]

Max. linewidth [THz]
10%

5000(3)

1.5
Measurement speed [Hz](5)
(depending on PC hardware and settings)
 

Data aquisition

Wavelength calculation

Linewidth calculation

Pattern display
400

20

20

15
  from - to
Required input energy [µJ]
(or power [µW])(6)
 
Standard

UV

IR
0.005-0.2

0.005-1

0.5-10
Defraction grating  
FSR (Ghz) ~5500
Coupling fiber diameter [µm] 50 µm or SM fiberset
Calibration Built-in calibration
Calibration period >1 month (will be detected and done automatically)
Warm-up time No warm-up time under constant ambient conditions
Dimensions L x W x H [mm] 325 x 180 x 77
Weight [kg] 2.8
Interface High-speed USB 2.0 connection
Power supply Power consumption <2.3 W, supply directly via USB cable

(1) With multi mode fiber   (2) Only for standard range of 370-1100nm   (3) But not better than 5% of the linewidth
(4) According to 3σ criteria   (5) Without auto-calibration usage   (6) The cw power interpretation in [µW] compares to an exposure of 1s (generally the energy needs to be divided by the exposure time to obtain the required power)

Available Options

» Linewidth option - L

Included in Delivery (standard version)

Optical unit LSA
USB connection cable (optical unit - computer)
1x 50µm Multimode fiber 5 m
2 singlemode fibers on choice (400nm, 460nm, 630nm, 780nm, 980nm avaible)
2x Collimators for coupling light into fibers
CD-ROM with userfriendly software for operation and measurement
Operation manual
Certificate

Links

» Demo Software
» LSA Product Sheet 2011 [PDF, 132 kB]
» LSA IR-3 Product Sheet 2011 [PDF, 130 kB]


back to top


Last update: 08.06.2011 © HighFinesse GmbH 2012