Laser spectrum Analyser - LSA

Absolute accuracy: 6000 MHz, resulution: 1000 MHz

 Sensitivity: 5 nJ @ 633 nm
 Low stage spectral resolution: (&lambda/&Delta&lambdaFWHM): 500
 High stage spectral resolution (&lambda/&Delta&lambdaFWHM): 20000 (SM fiber),
    10000 (50µm fiber)
 max. spectral range: 3 THz
 linewidth accuracy : 10%
    (min. linewidth &delta&lambda/&lambda= 2*10-5 (e.g. 10pm @ 633nm))
    (max. linewidth: 1.5 THz
 Built-in light source for autocalibration

The LSA is designed to analyse the multi-line or broadband spectrum of lighte sources like cw and pulsed lasers, gas discharge lamps, super luminescence diods, semiconductor laser diodes and LEDs.

Technical Data  LSA
Measurement range [nm]   Standard

UV

IR
370-1120

248-1100

800-1750


Absolute accuracy(g)  

248-370 nm [pm](a)

370-1100 nm [MHz]

IR(800-1750 nm) [MHz]
6


6000


12000
Quick coupling accuracy (with MM fiber) 12000
Wavelength deviation sensivity  

248-370 nm [pm](a)

370-1100 nm [MHz]

IR(800-1750 nm) [MHz]
5


3000


5000
Spectral resolution  

Standard, UV

IR
20000(SM),10000(MM)


4000(SM),2000(MM)
Linewidth High stage  

Accuracy (c)

Min. linewidth

Max. linewidth [THz]
10%


2*10-5


1.5
Measurement speed [Hz]
(depending on PC hardware and settings)
 

Data aquisition

Wavelength calculation

Linewidth calculation

Pattern display
400


20


20


15
  from - to
Required input energy [µJ]
(or power [µW])(11)
 
Standard

UV

IR
0.005-0.2

0.005-1

0.5-10
Defraction grating  
FSR(Ghz ~5500
Coupling fiber diameter [µm] 50 µm or SM fiberset
Calibration Built-in calibration
Calibration period >1 month (will be detected and done automatically)
Warm-up time No warm-up time under constant ambient conditions
Dimensions L x W x H [mm] 325 x 180 x 77
Weight [kg] 2.8
Interface High-speed USB 2.0 connection
Power supply Power consumption <2.3 W, supply directly via USB cable

(a) With MM fiber   (c) Only for standard range
(b) Values for wide-/fine-mode   (g) according 3&sigma criteria
(11) The cw power interpretation in [µW] compares to an exposure of 1 s.
       For other exposures, the energy needs to be divided by the exposure time to get the power.

Available Options

Linewidth option - L

Included in Delivery (standard version)

Optical unit LSA
USB connection cable (optical unit - computer)
1x 50µm Multimode fiber 5 m
2 singlemode fibers on choice (400nm, 460nm, 630nm, 780nm, 980nm avaible)
2x Collimators for coupling light into fibers
CD-ROM with userfriendly software for operation and measurement
Operation manual
Certificate

Links