WS6 High Precision

 Standard measurement range 350-1120 nm
 Relative accuracy 10-6
 Measurement speed 500 Hz
 Single integrated interferometer for compact design
 Capable of measuring cw and pulsed lasers
 Various options available

The WS6-Standard is a sensitive and compact wavelength meter for laser sources. It is capable of measuring pulsed and continuous laser sources. Both, optical elements and assigned electronics are housed in a compact, thermally isolated casing.

Easy Set-up

The WS6-Standard is connected to the PC via the USB interface. After installing the software delivered with the wavemeter, the device is ready for measurements. There is no warm-up time under constant ambient conditions.

Guaranteed Future

The design of the WS6-Standard permits the integration of additional optical components and software modules, allowing custom solutions for customer specific application even years after purchase.
For further particulars on the available options we refer you to our options page.

Technical Data  WS6-600 WS6-200
Measurement range [nm]   Standard
UV
IR
UV-II
IR-II
350-1120
248-1100
800-1750
192-800
1000-2250








Absolute accuracy 7)  

192-370 nm (pm) 1)
370-1100 nm (MHz)
1100-2250 nm (MHz)
0.6

600

400
0.4

200

150
Quick coupling accuracy
(with MM fiber)
600 600
Resolution (MHz) 100 50
Linewidth option 4)  

Accuracy (MHz) 3)

Max. bandwidth (GHz)
5% (>500) 4)


60
Measurement speed (Hz)
(depending on PC hardware and settings
 

Wavelenght

Interferometer picture

Linewidth option
300

80


20
150

40


10
Riquired input power(µJ)  

Standard
UV
IR
UV-II
IR-II
0.02-5
0.1-20
20-200
1-80
50-1000
0.06-15
0.03-60
3-200
50-1000
250-3000
Fizeau interferometers 2)  

FSR (GHz) 15 (100)
Grating Option 3)  

Spectral resolution (nm) 0.2 &mdash
Coupling fiber diameter (µm) 400 µm 400 µm or SM fiberset
Calibration Built-in calibration
Calibration period >1 month (will be detected and done automatically
Warm-up time No warm-up time under constant ambient conditions (except IR-II: <30 minutes warm-up time required) Otherw. until thermal and air pressure equilibriumis reached.
Dimensions L x W x H (mm) 325 x 180 x 77 360 x 120 x 120
Weight (Kg) 2.8
interface High-speed USB 2.0 connection
Power supply Power consumption <2.3 W, supply directly via USB cable
IR-II: external power supply included

1) With MM fiber 4) Max. accuracy in () for narrow lasers
2) Values for wide-/fine-mode 7) according 3&sigma criteria
3) Only for standard range

Available Options

Linewidth option - L
Diffraction grating option - D
Double-pulse option - DP
Multi channel switcher (up to eight channels) - MC
Laser-feedback-PID-controller - PID
External TTL trigger option - TTL

Included in Delivery (standard version)

Optical unit WS6-600 / WS6-200
USB connection cable (optical unit - computer)
1x 50µm, 1x 400µm Multimode fibers 5 m
Singlemode fiber set including 1x 630 nm, 1x 780nm, 1x 980 nm and 1x 1300nm
2x Collimators for coupling light into fibers
CD-rom with userfriendly software for operating and measuring
Operation manual
Certificate
Ne-lamp for calibration

Links

Demo Software
Product Sheets 2008.pdf [PDF-Version, 1.4 MB]


back to top


Last update: 20.10.2008 © HighFinesse GmbH 2009